BJGYV - VAPEX LATEX FLAT HOUSE PAINT ACCENT BASE

  • MSDS: BJGYV
  • Manufacturer: PRATT AND LAMBERT INC
  • Product Name: VAPEX LATEX FLAT HOUSE PAINT ACCENT BASE
  • National Stock Number: 8010-00F013040
Product Identification

Product ID:VAPEX LATEX FLAT HOUSE PAINT ACCENT BASE
MSDS Date:02/11/1986
FSC:8010
NIIN:00F013040
MSDS Number: BJGYV

Responsible Party
PRATT & LAMBERT, INC
BUFFALO, NY 14240

Emergency Phone: (716) 873-6000

Info Phone: (716) 873-6000

Cage: FO127

Contractor
PRATT AND LAMBERT INC
22 CLEVELAND, OH 44101-1027 US

Telephone: 216-566-2902

Cage: 61196

Ingredients

4.2 (CALCULATED)

RTECS: 9999999VO


ETHYLENE GLYCOL (SARA III)

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: <5.000%

OSHA PEL C 50 PPM

ACGIH TLV: C 50 PPM,VAPOR; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TALC, CALIFORNIA (MICROTALC, TALCRON, CERCRON)

CAS: 14801-96-6

Fraction By Weight: <0.100%


COMPLEX HYDROUS CALCIUM SILICATE

CAS: 14567-73-8

Fraction By Weight: <1.000%

ACGIH TLV: 2 MG/CUM


SILICA AMORPHOUS HYDRATED, SILICEOUS EARTH, FUMED

CAS: 112945-52-5

RTECS: VV7310000

Fraction By Weight: 30.000%

OSHA PEL 80 MG/CUM (%SIO2+2)

ACGIH TLV: 0.2 MG/CUM RESP/DUST

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: ABDOMINAL DISCOMFORT OR
PAIN, DIZZINESS, MALAISE, LUMBAR PAIN, OLIGURIA, UREMIA, CENTRAL
NERVOUS SYSTEM DEPRESSION, KIDNEY DAMAGE, FATAL/METABOLIC ACIDOSIS.
HEMODIALYSIS MAY BE REQUIRED. PU LMONARY EDEMA W/HYPOXEMIA HAS BEEN
DESCRIBED IN A NUMBER OF PATIENTS FOLLOWING POISONING W/ETHYLENE
GLYCOL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: REPEATED EXPOSURE TO CRYSTALLINE
SILICA MAY CAUSE PNEUMOCONIOSIS, A PROGRESSIVELY DISABLING LUNG
DISEASE.
Medical Cond Aggravated by Exposure:LUNG DISEASE

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. INGESTION: INDUCE VOMITING
BY GIVING 2 GLASSES OF WATER/STICKING FINGER DOWN THROAT. CONSULT
PHYSICIAN. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
EYES: FL USH W/WATER UNTIL RELIEVED. CONSULT PHYSICIAN.

Fire Fighting

Flash Point Method:SCC
Flash Point:>200F

Accidental Release

Spill Release Procedures:CONFINED IN SMALL AREA; USE ABSORBENT TO CLEAN
UP. PLACE IN CONTAINER FOR DISPOSAL.

Handling

Handling and Storage Precautions:PROTECT FROM FREEZING OR EXTREMELY
HIGH TEMPERATURES. DON'T TAKE INTERNALLY. CLOSE CONTAINER AFTER
EACH USE. KEEP AWAY FROM CHILDREN.

Exposure Controls

Respiratory Protection:NOT NEEDED
Ventilation:NATURAL VENTILATION SHOULD BE ADEQUATE UNDER NORMAL
CONDITIONS.
Protective Gloves:NOT NEEDED
Eye Protection:FACE SHIELD, GOGGLES
Other Protective Equipment:NOT NEEDED
Supplemental Safety and Health
WT/GAL: 10.8.

Chemical Properties

Boiling Pt:B.P. Text:28-430F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:59%

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT, FREEZING OR EXTREMELY HIGH
TEMPERATURES
Hazardous Decomposition Products:SMOKE, CO, CO2

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS. AS PRODUCED, THIS PRODUCT ISN'T A WASTE. IF
DISCARDED AS IS, IT ISN'T CLASSIFIED A HAZARDOUS WASTE UNDER RCRA.
COMBUSTIBLE LIQUID - CLASS IIIB.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.